Bosch Outdoor Dome Cameras

2
  • Excellent resolution (570 TVL sensor resolution)
  • Three versions for all lighting environments
  • Flexible viewing field
  • Easy setup
  • Secure all-weather installation

The VDx-240 Outdoor Dome range comes in robust,conduit compatible, all-weather housings (IP66 rated) and provides high-resolution images (570TVL Sensor Resolution).
The color version provides crisp, clear images in applications with sufficient lighting. The day/night version switches to monochrome mode with ahigher light sensitivity when there is insufficientlighting. For applications requiring extra lighting,the infrared version has 20 on-board IR LEDs providing 20 meters of night vision.

Outdoor Dome Camera

Video

CCD Camera 1/3-inch High Sensitivity CCD
Effective pixels (HxV) 752X582 (PAL) 768x494 (NTSC)
Horizontal Resolution 570 TVL Sensor Resolution
Electronics Iris 1/50 to 1/120,000 s (PAL) 1/60 to 1/120,000 s (NTSC)
Manual shutter 1/50 (1/60), 1/100 (1/120), 1/250, 1/500, 1/700, 1/1K, 1/1.6k, 1/2.5K, 1/5K. 1/7K 1/10K, 1/30K, 1/60K, 1/120K
Output Signal 1 VPP composite video, 75 ohm
Output connection BNC connector
S/N Ratio Greater than 50db
Gamma 0.35, 0.45 (default), 0.6, 0.75
Lens (VDC-240 2.8 to 10.5 mm varifocal auto-iris
Lens (VDN-240) 2.8 to 10.5 mm varifocal auto-iris with mechanical D/N filter
Lens (VDI-240) 3.8 to 9.5 mm varifocal auto-iris with mechanical D/N filter
Sensitivity 0.05 lx (color), 0.005 lx (b/w), 0 lx (infrared on)
LEDs Intelligent 20-LED infrared array Wavelength 850
Wavelength 850nm
Housing Surface mount dome, vandal resistant
Giambls 3D gimbal for easy installation
Construction Robust aluminum
Finish Off-white
Conduit Compatible 1/2‑inch PT, top and side
Power Consumption VDC-240: 3.6 W max. VDN-240: 3.6 W max. VDI-240: 6 W max. VDI-240 (with heater): 17.5 W max.
Voltage 12 VDC or 24 VAC
Power Supply not included
Operating Temperature `-10 °C to +50 °C B35(14 ºF to +122 ºF)
Operational Temp. (VDI-240 with heater) `-30 °C to +50 °C (-22 ºF to +122 ºF)
Storage Temperature `-20 °C to +60 °C (-4 ºF to +140 ºF)
Environment IP66 certified

Region /Certification

Europe CE
Standards ANSI C63.4: 2009 FCC Part 15 subpart B, Class A UL 60065, 7th Edition. 2007-12-11 CAN/CSA-C22.2 No. 60065-03, 1st Edition, 2006-04 + A1:2006 EN55022:2006, Class A EN50130-4:1995+A1:1998+A2:2003 LVD 2006/95/EC EN60065:2002 + A1:2006 + A11:2008 IP66, IEC 60529 (2001), IEC 60529 (2002)

User Manual